TeSys LRD thermal overload relay, 25A/690V, thermal setting range 17-25A, tripping class 20, for protection of 3-phase motors 9-11kW@400V. Differential device with phase failure (loss). It provides a thermal adjustment dial, a manual-automatic reset selector, a test selector for simulation of a trip..
5,780.68 EGP
TeSys LRD thermal overload relay, 4A/690V, thermal setting range 2.5-4A, tripping class 20, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a t..
5,179.25 EGP
TeSys LRD thermal overload relay, 28A/690V, thermal setting range 23-28A, tripping class 20, for protection of 3-phase motors 9-11kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tri..
9,030.20 EGP
TeSys LRD thermal overload relay, 32A/1000V, thermal setting range 23-32A, tripping class 10A, for protection of 3-phase motors 15kW@400V. Non differential device, it can be used with unbalanced loads. It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset but..
4,894.17 EGP
TeSys LRD thermal overload relay, 32A/690V, thermal setting range 25-32A, tripping class 20, for protection of 3-phase motors 15kW@400V. Differential device with phase failure (loss). It provides a thermal adjustment dial, a manual-automatic reset selector, a test selector for simulation of a trippi..
9,011.86 EGP
TeSys LRD thermal overload relay, 40A/1000V, thermal setting range 30-40A, tripping class 20, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector ..
9,873.92 EGP
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 20, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a trippin..
5,179.25 EGP
TeSys LRD thermal overload relay, 8A/690V, thermal setting range 5.5-8A, tripping class 20, for protection of 3-phase motors 3kW@400V. Differential device with phase failure (loss). It provides a thermal adjustment dial, a manual-automatic reset selector, a test selector for simulation of a tripping..
5,179.25 EGP
TeSys LRD thermal overload relay, 70A/1000V, thermal setting range 55-70A, tripping class 20, for protection of 3-phase motors 30kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector fo..
10,191.84 EGP
TeSys LRD thermal overload relay, 80A/1000V, thermal setting range 63-80A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Non differential device, it can be used with unbalanced loads. It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset but..
7,538.42 EGP
TeSys LRD thermal overload relay, 80A/1000V, thermal setting range 63-80A, tripping class 20, for protection of 3-phase motors 37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector fo..
11,212.86 EGP
TeSys LRD thermal overload relay, 10A/690V, thermal setting range 7-10A, tripping class 20, for protection of 3-phase motors 4kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a trippin..
5,179.25 EGP