Shop Now
Your Cart

Power Components

TeSys GV motor circuit breaker, 3 poles (3P), 23A/690V, for 3-phase motor applications 9kW@400V. It provides a thermal-magnetic protection with a thermal setting range 17-23A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by..
5,230.55 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 2.5-4A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop cont..
2,751.25 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 2.5-4A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop cont..
3,874.40 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a thermal-magnetic protection with a thermal setting range 20-25A, magnetic tripping at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control b..
3,311.69 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a thermal-magnetic protection with a thermal setting range 20-25A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control b..
6,053.94 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V. It provides a thermal-magnetic protection with a thermal setting range 24-32A, magnetic tripping at 13xIn, high breaking capacity Icu 10kA@400V. Connection by screw clamp terminals. Start-stop control b..
5,465.81 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V. It provides a thermal-magnetic protection with a thermal setting range 24-32A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control b..
7,192.80 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for 3-phase motor applications 2.2kW@400V. It provides a thermal-magnetic protection with a thermal setting range 4-6.3A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop contro..
2,751.25 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for 3-phase motor applications 2.2kW@400V. It provides a thermal-magnetic protection with a thermal setting range 4-6.3A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop contro..
3,874.40 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for 3-phase motor applications 3-4kW@400V. It provides a thermal-magnetic protection with a thermal setting range 6-10A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control ..
2,872.63 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for 3-phase motor applications 3-4kW@400V. It provides a thermal-magnetic protection with a thermal setting range 6-10A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control ..
4,296.20 EGP
TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for 3-phase motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-14A, magnetic tripping at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control b..
2,872.63 EGP
Showing 1573 to 1584 of 2371 (198 Pages)
document.addEventListener('DOMContentLoaded', function () {// Only show the button when the RFQ form exists on the product page const quotationForm = document.querySelector('#rfq-form-product');if (!quotationForm) { return; }// Prevent duplicate buttons if (document.querySelector('#request-quotation-scroll')) { return; }// Create button const quoteButton = document.createElement('button');quoteButton.id = 'request-quotation-scroll'; quoteButton.type = 'button'; quoteButton.className = 'btn request-quotation-scroll';quoteButton.innerHTML = ' REQUEST QUOTATION';// Smooth scroll quoteButton.addEventListener('click', function (e) {e.preventDefault();const form = document.querySelector('#rfq-form-product');if (!form) { return; }// Offset for sticky header const headerOffset = 120;const position = form.getBoundingClientRect().top + window.pageYOffset - headerOffset;window.scrollTo({ top: position, behavior: 'smooth' });});/* * Try to place it next to the QUESTION button */ const buttons = document.querySelectorAll( 'button, a.btn, .btn' );let questionButton = null;buttons.forEach(function (button) {const text = button.textContent .trim() .toUpperCase();if (text.includes('QUESTION')) { questionButton = button; }});if (questionButton) {questionButton.insertAdjacentElement( 'afterend', quoteButton );return; }/* * Fallback: * put it next to Add To Cart */ const cartButton = document.querySelector('#button-cart');if (cartButton) {cartButton.insertAdjacentElement( 'afterend', quoteButton );}});