Shop Now
Your Cart

ATV340D18N4E Variable speed drive, Altivar Machine ATV340, 18 kW Heavy Duty, 400 V, 3 phases, Ethernet

ATV340D18N4E Variable speed drive, Altivar Machine ATV340, 18 kW Heavy Duty, 400 V, 3 phases, Ethernet
ATV340D18N4E Variable speed drive, Altivar Machine ATV340, 18 kW Heavy Duty, 400 V, 3 phases, Ethernet
118,228.00 EGP
  • Stock: In Stock
130 Course Regisered
10001041 Views Page

Price Includes VAT

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 18.5kW / 25hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 10.2kg and its dimensions are, 180mm wide, 385mm high, 249mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM)


FOR MOE DETAILS CLICK  here

Main
Range of ProducAltivar Machine ATV340
Product or Component TypeVariable speed drive
VariantStandard version
communication port protocolEtherNet/IP Modbus TCP Modbus serial
[Us] rated supply voltage380...480 V - 15...10 %
output current39.0 A
Motor power kW22 kW for normal duty 18.5 kW for heavy duty
EMC filterClass C3 EMC filter integrated
IP degree of protectionIP20
Complementary
Discrete input number5
Discrete input typePTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V) DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm programmable
Discrete output number2.0
Discrete output typeProgrammable output DQ1, DQ2 30 V DC 100 mA
Analogue input number2
Analogue input typeAI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output typeRelay outputs R1A Relay outputs R1C electrical durability 100000 cycles Relay outputs R2A Relay outputs R2C electrical durability 100000 cycles
Maximum switching currentRelay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching currentRelay output R1B: 5 mA at 24 V DC Relay output R2C: 5 mA at 24 V DC
Method of accessSlave Modbus RTU Slave Modbus TCP
4 quadrant operation possibletrue
Asynchronous motor control profileVariable torque standard Constant torque standard Optimized torque mode
Synchronous motor control profileReluctance motor Permanent magnet motor
Transient overtorque170…200 % of nominal motor torque
output frequency0.599 kHz
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s S, U or customized
Motor slip compensationAdjustable Automatic whatever the load Can be suppressed Not available in permanent magnet motor law
Switching frequency2...16 kHz adjustable 4...16 kHz with derating factor
Braking to standstillBy DC injection
Nominal switching frequency4 kHz
Brake chopper integratedTrue
Line current43.4 A at 380 V (normal duty) 35.0 A at 480 V (normal duty) 54.7 A at 380 V (heavy duty) 43.4 A at 480 V (heavy duty)54.7 A at 380 V without line choke (heavy duty) 43.4 A at 480 V without line choke (heavy duty) 49.9 A at 380 V with external line choke (normal duty) 40.2 A at 480 V with external line choke (normal duty) 54.5 A at 480 V with external line choke (heavy duty) 43.5 A at 380 V with external line choke (heavy duty)
Maximum Input Current per Phase54.7 A
Maximum output voltage480 V
supply Frequency50...60 Hz +/- 5 %
Base load current at high overload39.0 A
Power dissipation in WNatural convection: 21 W at 380 V, switching frequency 4 kHz (heavy duty) Forced convection: 410 W at 380 V, switching frequency 4 kHz (heavy duty) Natural convection: 23 W at 380 V, switching frequency 4 kHz (normal duty) Forced convection: 464 W at 380 V, switching frequency 4 kHz (normal duty)
With safety function Safely Limited Speed (SLS)True
With safety function Safe brake management (SBC/SBT)True
With safety function Safe Stop 1 (SS1)True
With safety function Safe torque off (STO)True
Protection typeThermal protection: motor Safe torque off: motor Motor phase loss: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive Motor phase loss: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Exceeding limit speed: drive Break on the control circuit: drive
Physical
Height385.0 mm
Width180.0 mm
Depth249.0 mm
Mounting modeCabinet mount

Write a review

Please login or register to review
Tags: ATV340 , Altivar
This Easy Altivar 310 drive is a frequency inverter for three-phase asynchronous motors. Its protection index is IP20. It works at a rated power up to..
19,492.00 EGP
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 dri..
169,664.00 EGP
This Schneider Electric Easy UPS SRV Battery Pack, connected with compatible SRV On-Line UPS, provides extended runtime during prolonged power outages..
47,080.00 EGP
For small to medium businesses, Easy UPS 1 Ph On-Line provides essential power protection for unstable power conditions, ensuring consistent and relia..
105,204.00 EGP
This Altivar 320 variable speed drive can feed 3-phase synchronous and asynchronous motors. Its compact form factor allows vertical stacking of drives..
25,520.00 EGP
View Time GraphFor small to medium businesses, Schneider Electric offers this single phase Easy UPS designed for essential power protection needs even..
140,800.00 EGP
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 dri..
112,948.00 EGP
For small to medium businesses, Easy UPS 1 Ph On-Line provides essential power protection for unstable power conditions, ensuring consistent and relia..
141,240.00 EGP
Time GraphFor small to medium businesses, Easy UPS 1 Ph On-Line provides essential power protection for unstable power conditions, ensuring consistent..
149,600.00 EGP